| Sign In | Join Free | My benadorassociates.com | 
 | 
Brand Name : Daruifuno
Model Number : OZ1.2
Certification : CE, ISO
Place of Origin : China
MOQ : Negotiable
Price : Negotiable
Payment Terms : T/T
Delivery Time : 1-45 work days
Packaging Details : carton
Product Name : Ozone sensor
Product Model : OZ1.2
Measuring range : 0~0.5/2/5/10/20ppm
Pressure Range : 0 ~ 1bar (Flow cell)
Temperature Range : 0 ~ 45 ℃
Response Time : T90: approx. 3 min. (brine approx. 5 min.)
Flow Rate : 15-30 l/h (33 – 66 cm/s)
Two-Wire 4-20mA Two-Electrode Ozone Sensor For Drinking Water, Direct Drinking Water, Service Process Water
Two-electrode system ozone sensor OZ1.2, used in drinking water, direct drinking water, service and process water, measuring water without surfactant, optional range 0~0.5/2/5/10/20ppm
The functional characteristics of the ampere film ozone sensor include high sensitivity and fast response, which can accurately measure the ozone concentration in water. Its advantages are strong anti-interference ability, suitable for various water quality environments, and long service life. It is suitable for drinking water and industrial water treatment to ensure water quality safety.

Specifications
|  | 
 
 OZ1.2 | 
| Indicator | Ozone | 
| Application | Swimming pool water, drinking water, service water, process water | 
| Measuring system | Membrane covered, amperometric 2-electrode system | 
| 
 
 
 
 Electronic | Analog version: - voltage output - not galvanically isolated electronics - analog internal data processing - output signal: analog (analog-out/analog) Digital version: - electronic is completely galvanically isolated - digital internal data processing - output signal: analog (analog-out/digital) or digital (digital-out/digital) mA-version: - current output analog - not galvanically isolated electronics - output signal: analog (analog-out/analog) | 
| 
 Information about the measuring range | The actual slope of a sensor can vary production-related between 65% and 150% of the nominal slope Note: With a slope > 100% the measuring range is reduced accordingly. (Ex.: 150% slope → 67% of the specified measuring range) | 
| Slope drift At repeatability conditions (25 °C, pH 7,2 in drinking water) | Approx. <- 1% per month | 
| 
 Working temperature | Measuring water temperature: 0 … +45 °C (no ice crystals in measuring water) | 
| Ambient temperature: 0 … +55 °C | |
| Temperature compensation | Automatically, by an integrated temperature sensor | 
| 
 
 Max. allowed working pressure | Operation without retaining ring: - 0.5 bar - no pressure impulses and/or vibrations | 
| Operation with retaining ring in Flow cell: - 1.0 bar, - no pressure impulses and/or vibrations (see option 1) | 
|  | 
 
 OZ1.2 | |||
| Flow rate (Incoming flow velocity) | Approx. 15-30 l/h (33 – 66 cm/s) in flow FLC, small flow rate dependence is given | |||
| pH-range | pH 1 – pH 11 | |||
| Run-in time | First start-up approx. 1 h | |||
| Response time | T90 : approx. 15 sec. | |||
| Zero point adjustment | Not necessary | |||
| Calibration | At the device, by analytical determination | |||
| Interferences | Cl2: factor 0.03 | |||
| Absence of the disinfectant | Max. 24 h | |||
| 
 Connection | mV version: Modbus version: 4-20 mA version: | 5-pole M12, plug-on flange 5-pole M12, plug-on flange 2-pole terminal or 5-pole M12, plug-on flange | ||
| max. length of sensor cable (depending on internal signal processing) | analog | < 30 m | ||
| digital | > 30 m are permissible Maximum cable length depends on application | |||
| Protection type | 5-pole M12 plug-on flange: IP68 2-pole terminal with mA-hood: IP65 | |||
| Material | Semipermeable membrane, PVC-U, ABS | |||
| 
 
 Size | Diameter: Length: mV version Modbus version 4-20 mA version | approx. 25 mm approx. 190 mm (analog signal processing) approx.. 205 mm (digital signal processing) approx. 205 mm approx. 220 mm (2-pole-terminal) approx. 190 mm (5-pole-M12) | ||
| Transport | +5 … +50 °C (sensor, electrolyte, membrane cap) | |||
|  | 
 
 OZ1.2 | 
| 
 
 Storage | Sensor: dry and without electrolyte no limit at +5 … +40 °C | 
| Electrolyte: in original bottle protected from sunlight at +5 … +35 °C min. 1 year or until specified EXP-Date | |
| Membrane cap: in original packing no limit at +5 … +40 °C (used membrane caps can not be stored) | |
| 
 Maintenance | Regularly control of the measuring signal, min. once a week The following specifications depend on the water quality: Change of the membrane cap: once a year (depending on the water quality) Change of the electrolyte: every 3 - 6 months | 
|  | 
| Option 1: Retaining ring | 
 
 
 
 - When operating with pressures >0.5 bar in flow cell - Dimensions retaining ring 29 x 23.4 x 2.5 mm, slitted, PETP - Different positions for groove selectable(on request) | 
 
 |  | 
Technical Data
1. OZ1.2 (analog output, analog internal signal processing)
 A potential-free electrical connection is necessary as the sensor electronic is not equipped with a galvanical
 isolation.
|  | Measuring range in ppm | Resolution in ppm | Output Output resistance | Nominal slope in mV/ppm | Voltage supply | Connection | 
| OZ1.2H-M12 | 0.005…2.000 | 0.001 | 
 
 0…-2000 mV 1 kΩ | - 1000 | 
 
 ±5 - ±15 VDC 10 mA | 5-pole M12 plug-on flange 
 Function of wires: PIN1: measuring signal PIN2: +U PIN3: -U PIN4: signal GND PIN5: n. c. | 
| OZ1.2N-M12 | 0.05…20.00 | 0.01 | - 100 | |||
| OZ1.2HUp-M12 | 0.005…2.000 | 0.001 | 
 
 0…+2000 mV 1 kΩ | +1000 | 
 
 10 - 30 VDC 10 mA | 5-pole M12 plug-on flange Function of wires: 
 PIN1: measuring signal PIN2: +U PIN3: power GND PIN4: signal GND PIN5: n. c. | 
| OZ1.2NUp-M12 | 0.05…20.00 | 0.01 | +100 | 
(Subject to technical changes!)
2.  OZ1.2 (analog output, digital signal processing)
 Analog-out / digital
 -The power supply is galvanically isolated inside of the sensor.
 -The output signal is galvanically isolated too, that means potential-free.
|  | Measuring range in ppm | Resolution in ppm | Output Output resistance | Nominal Slope in mV/ppm | Power supply | Connection | 
| OZ1.2H-An-M12 | 0.005…2.000 | 0.001 | analog 0…-2 V (max. -2.5 V) 1 kΩ | - 1000 | 
 
 9-30 VDC approx. 20-56 mA | 5-pole M12 plug-on flange 
 Function of wires: PIN1: measuring signal PIN2: +U PIN3: power GND PIN4: signal GND PIN5: n. c. | 
| OZ1.2N-An-M12 | 0.05…20.00 | 0.01 | - 100 | |||
| OZ1.2H-Ap-M12 | 0.005…2.000 | 0.001 | analog 0…+2 V (max. +2.5 V) 1 kΩ | +1000 | ||
| OZ1.2N-Ap-M12 | 0.05…20.00 | 0.01 | +100 | 
(Subject to technical changes!)
3. OZ1.2 (digital output, digital signal processing)
 -The power supply is galvanically isolated inside of the sensor.
 -The output signal is galvanically isolated too, that means potential-free.
|  | Measuring range in ppm | Resolution in ppm | Output Output resistance | Power supply | Connection | 
| OZ1.2H-M0c | 0.005…2.000 | 0.001 | Modbus RTU 
 There are no terminating resistors in the sensor. | 9-30 VDC 
 approx. 20-56 mA | 5-pole M12 plug-on flange Function of wires: PIN1: reserved PIN2: +U PIN3: power GND PIN4: RS485B PIN5: RS485A | 
| OZ1.2N-M0c | 0.05…20.00 | 0.01 | 
(Subject to technical changes!)
4. OZ1.2 4-20 mA (analog output, analog internal signal processing)
 A potential-free electrical connection is necessary as the sensor electronic is not equipped with a galvanical
 isolation.
 4.1 Electrical connection: 2 pole terminal clamp
|  | Measuring range in ppm | Resolutio n in ppm | Output Output resistance | Nominal slope in mA/ppm | Voltage supply | Connection | 
| OZ1.2MA0.5 | 0.005…0.500 | 0.001 | 4…20 mA uncalibrated | 32.0 | 
 12…30 VDC RL 50Ω…RL 900Ω | 
 2-pole terminal (2 x 1 mm²) 
 Recommended: Round cable 4 mm 2 x 0.34 mm² | 
| OZ1.2MA2 | 0.005…2.000 | 0.001 | 8.0 | |||
| OZ1.2MA5 | 0.05…5.00 | 0.01 | 3.2 | |||
| OZ1.2MA10 | 0.05…10.00 | 0.01 | 1.6 | |||
| OZ1.2MA20 | 0.05…20.00 | 0.01 | 0.8 | 
(Subject to technical changes!)
4.2 Electrical connection: 5 pole M12 plug-on flange
|  | Measuring range in ppm | Resolution in ppm | Output Output resistance | Nominal slope in mA/ppm | Voltage supply | Connection | 
| OZ1.2MA0.5-M12 | 0.005…0.500 | 0.001 | 4…20 mA uncalibrated | 32.0 | 12…30 VDC RL 50Ω…RL 900Ω | 5-pole M12 plug- on flange 
 Function of wires: PIN1: n. c. PIN2: +U PIN3: -U PIN4: n c. PIN5: n. c. | 
| OZ1.2MA2-M12 | 0.005…2.000 | 0.001 | 8.0 | |||
| OZ1.2MA5-M12 | 0.05…5.00 | 0.01 | 3.2 | |||
| OZ1.2MA10-M12 | 0.05…10.00 | 0.01 | 1.6 | |||
| OZ1.2MA20-M12 | 0.05…20.00 | 0.01 | 0.8 | 
(Subject to technical changes!)
Spare Parts
| Type | Membrane cap | Electrolyte | Emery | O-ring | 
| For all OZ1.2 | M20.2 | EOZ1/W, 100 ml Art. no. 11101 | S1 | 14 x 1.8 silicone | 
(Subject to technical changes!)
|   | 
| Two-Wire 4-20mA Two-Electrode Ozone Sensor For Drinking Water, Direct Drinking Water, Service Process Water Images | 
 30L / H Hydrogen Peroxide Sensor Water Quality Probe Surfactant Resistant
                                                                                    
                        
                        
                        
                                                            30L / H Hydrogen Peroxide Sensor Water Quality Probe Surfactant Resistant
                                                    
                        
                     Total Chlorine Sensor Membrane Covered Water Quality Sonde 4 ~ 12pH
                                                                                    
                        
                        
                        
                                                            Total Chlorine Sensor Membrane Covered Water Quality Sonde 4 ~ 12pH
                                                    
                        
                     Chlorite Sensor Water Quality Probe Amperometric 3 Electrode
                                                                                    
                        
                        
                        
                                                            Chlorite Sensor Water Quality Probe Amperometric 3 Electrode
                                                    
                        
                     T90 15s Ozone Sensor Water Quality Sonde 2 ~ 11pH
                                                                                    
                        
                        
                        
                                                            T90 15s Ozone Sensor Water Quality Sonde 2 ~ 11pH
                                                    
                        
                     2 Electrode Chlorine Dioxide Sensor Membrane Covered Water Quality Probe
                                                                                    
                        
                        
                        
                                                            2 Electrode Chlorine Dioxide Sensor Membrane Covered Water Quality Probe
                                                    
                        
                     Peracetic Acid Sensor 60℃ Water Quality Probe Tolerate Surfactants
                                                                                    
                        
                        
                        
                                                            Peracetic Acid Sensor 60℃ Water Quality Probe Tolerate Surfactants
                                                    
                        
                     Two-Electrode System Peracetic Acid Sensor For All Water Treatments High
                                                                                        
                                                        
                        
                        
                        
                                                            Two-Electrode System Peracetic Acid Sensor For All Water Treatments High
                                                    
                        
                     Membrane Coated Peracetic Acid Sensor With High Chemical Resistance For All
                                                                                        
                                                        
                        
                        
                        
                                                            Membrane Coated Peracetic Acid Sensor With High Chemical Resistance For All
                                                    
                        
                     11pH Water Quality Sonde Ozone Sensor For The Measurement Of Dissolved Ozone
                                                                                    
                        
                        
                        
                                                            11pH Water Quality Sonde Ozone Sensor For The Measurement Of Dissolved Ozone
                                                    
                        
                     4 ~ 9pH Chlorine Sensor Water Quality Sensor With Membrane Covered
                                                                                    
                        
                        
                        
                                                            4 ~ 9pH Chlorine Sensor Water Quality Sensor With Membrane Covered